Marco Beghini ; Tommaso Grossi ; Ciro Santus ; Emilio Valentini - Revealing systematic errors in hole drilling measurements through a calibration bench: the case of zero-depth data

jtcam:10080 - Journal of Theoretical, Computational and Applied Mechanics, June 6, 2023 - https://doi.org/10.46298/jtcam.10080
Revealing systematic errors in hole drilling measurements through a calibration bench: the case of zero-depth dataArticle

Authors: Marco Beghini ORCID1; Tommaso Grossi ORCID1; Ciro Santus ORCID1; Emilio Valentini 2

  • 1 University of Pisa - Università di Pisa
  • 2 SINT Technology Srl

An accurate estimation of the measurement error in the hole drilling method is needed to choose an appropriate level of regularization and to perform a sensitivity analysis on the stress results. The latest release of ASTM E837 standard for the hole drilling method includes a procedure aimed at estimatingthe standard deviation of the random error component on strain measurements, proposed by Schajer. Nevertheless, strain measurements are also affected to some extent by systematic errors which are not included in the estimation and need to be compensated. For example, an error in the rosette gage factor orin the identification of the zero-depth datum systematically affects all strain measurements in a strongly correlated fashion. This paper describes a calibration bench, designed to superimpose a reference bending stress distribution on a given specimen while simultaneously performing a hole drilling measurement.Since the reference solution is known a priori and shares the measurement instrumentation, the hole geometry and the stepping process with the actual residual stress distribution, the bench provides the user with a direct validation of the obtained accuracy. In addition, strategies aimed at compensating systematicerrors can be tested on the reference solution and then applied on the residual stress evaluation. The imperfect hole geometry and drilling alignment are proven to cause a significant underestimation of stresses near the surface, as they lead to an incorrect identification of the zero-depth datum. It is shown that this effect can be corrected through the proposed calibration bench.


Published on: June 6, 2023
Accepted on: May 4, 2023
Submitted on: September 26, 2022
Keywords: Residual stress,Hole drilling,Bench,Systematic errors,[SPI]Engineering Sciences [physics],[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph],[SPI.MECA.MEMA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of materials [physics.class-ph]

Consultation statistics

This page has been seen 380 times.
This article's PDF has been downloaded 291 times.